Two Standard Methods in one Unit
The haze-gard dual objectively measures Total Transmittance
and Transmission Haze according to two international specifications:
– ISO 13468 Compensation method
– ASTM D 1003 Non-compensated method
Fast Measurement of a Variety of
Samples
Open sample area for small and large specimens
Foot switch and automatic measurement allow hands-
free operation
Built-in statistics with average, standard deviation,
coefficient of variance, and min/max
Large storage capacity and data transfer to a printer or PC for professional
documentation
Operation in English, German, French, Spanish, and
Italian - switchable
|
Precise
and Reliable Readings – Any
time
Total Transmittance and Transmission Haze in one unit
Reference beam, self-diagnosis and enclosed optics
guarantee accurate readings
Ready for measurement without warm-up time
Automatic and long-term calibration guarantee reliable
readings |
|
ASTM
D 1003
Measurement conditions are different during calibration and actual measurement.
During calibration, part of the light escapes through the open entrance port.
While taking a measurement, the entrance port is covered with the sample. Thus,
the amount of light in the sphere is increased by the light reflected at the
sample surface.
ISO 13468
Measurement conditions are kept equal during calibration and measurement
due to an additional opening in the sphere.
During calibration the sample is placed at the compen- sation port. For
the actual measurement, the sample is changed to the entrance port. Thus,
the socalled sphere efficiency is independent of the reflection properties
of the sample.
Note:
Differences between the two methods can be approximately 2 % Total
Transmittance on clear, glossy samples.
|
| Training
haze-gard dual
BYK-Gardner offers you more than just an instrument. We assist you in
operation of the haze-gard dual and understanding your appearance readings.
As a
result you will be able to use the system to save time and money and at
the same time improve your quality. Therefore, the instrument comes with
a half day training course including:
Haze and Clarity Theory
Visual perception, Transparency, Scattering, Haze, and
Clarity
Instrumental measurement, Standards and Application
Operation and Software Training
Handling, Statistics, Maintenance
Direct data transfer to Excel® and documentation
|
|
|
The
Objective Standard for a Clear View
The haze-gard plus quantifies the
visual perception with objective measurement data. All essential criteria
for transparency can be measured with one instrument:
Total transmittance
Transmission haze
See-through quality
The Industry Standard according to ASTM
Reference beam, self-diagnosis, and enclosed optics guarantee accurate
readings – any time
Built-in statistics with average, standard deviation, coefficient of
variance, and min/max
Large storage capacity and data transfer to a printer or PC for professional
documentation
Quick Measurement of Variety of Samples
Open sample area for small and large specimens
Foot switch and automatic measurement allow hands- free operation
Ready for measurement without warm-up time Automatic and long-term calibration
allow easy and fast operation
Operation in English, German, French, Spanish and
Italian – switchable
|
Documentation of Measurement Data
The software easy-link transfers data to the PC for further data
processing in Excel® (see page 20).
|
|
|
Training haze-gard plus
BYK-Gardner offers you more than just an instrument. We assist you in operation
of the haze-gard plus and understanding your appearance readings. As a
result you will be able to use the system to save time and money and at
the same time improve your quality. Therefore, the instrument comes with
a half day training course including:
Haze and Clarity Theory
Visual perception, Transparency, Scattering, Haze, and Clarity Instrumental
measurement, Standards and Application
Operation and Software Training
Handling, Statistics, Maintenance
Direct data transfer to Excel® and documentation
|

Exact positioning of films
with a holder guided in a
precision track system.
|

Liquids are best measured using cuvettes and the cuvettetable.
|

The measurement of haze is used to determine abrasion resistance of transparent
materials. The Taber Abrasion Holder facilitates positioning of the abraded
area in the measurement beam.
|
|